OCTAX Log & Guard™

Производитель: MTG
Модель: OCTAX Log & Guard™
Наличие: Есть в наличии

The implementation of quality control (QC) and quality management systems in IVF, andrology and cryopreservation labs started more than two decades ago. In the meantime, being ISO certified has not only become a common standard in the field but is a mandatory part of many guidelines and even law. If done by hand, QC procedures can be time consuming and cumbersome. Our products assist you in increasing the accuracy of your measurements. To a large extent, monitoring of critical devices and processes can even be fully automated.

OCTAX Log & Guard™ is a monitoring and alarming system which has been specifically designed to meet the needs of quality control in A.R.T. All critical culture and storage parameters are continuously measured and documented through a network of external sensors:

  • Temperature inside incubators, fridges, freezers, liquid nitrogen storage tanks

  • Ambient temperature and humidity

  • Ambient VOC

  • CO2 from incubators

  • O2 from incubators (reduced oxygen atmosphere)

  • pH of culture media (via pH Online™)

Power supply is constantly monitored in the background. In case any of the values exceeds the pre-defined normal range, Log & Guard™ will rise visual and audible alarms and send a text message to up to four mobile phones. Avoiding an additional PC, the system operates on a web interface based software platform which is easily accessible from any computer in your local network. Alarming conditions and thresholds, measurement intervals and many other parameters can be set individually to perfectly adapt the monitoring network to your individual lab. For long term storage, measured data can be converted into MS Excel files. Log & Guard™ is highly flexible and extendible with respect to the kind and number of external sensors to be connected.

# 14840 / 0000 
OCTAX log & Guard™ Controller for monitoring and alarming

With integrated PC, GSM modem, battery backup; interfaces for temperature, CO2 and O2 sensors, pH Online™, external keyboard and flat screen, 8 alarm relay inputs; LAN interface, slot for SIM card (to be provided by the user for activating the text message alarming)

Caption

Technical data: power supply 110-240 V AC via external power adapter, external dimensions 260 x 300 x 90 mm (LxWxH), LCD display, battery service life approx. 20 min

# 14840 / 0200 
OCTAX Log & Guard™ temperature logger

for conventional incubators, fridges, freezers; starter kit Pt1000 sensor, temperature range -50 to +150°C, accuracy ± 0.5°C, resolution 0.1°C; battery backed (12 years battery life), cpl. with level converter supporting up to nine loggers; dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD)

# 14840 / 0201
OCTAX Log & GuardTM temperature logger

for conventional incubators, fridges, freezers; additional device Pt1000 sensor, temperature range -50 to +150°C, accuracy ± 0.5°C, resolution 0.1°C; battery backed (12 years battery life); dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD)

 

 

Caption

# 14840 / 0402 
OCTAX Log & Guard™ temperature logger

for K-Systems G185ST or Planer Bt37 benchtop incubators; starter kit Pt1000 sensor, temperature range -199 to + 199°C, accuracy ± 0.5°C, resolution 0.1°C; battery backed (12 years battery life), cpl. with level converter supporting up to nine loggers; dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD)

# 14840 / 0403 
OCTAX Log & Guard™ temperature logger

for K-Systems G185ST or Planer Bt37 benchtop incubators; additional device Pt1000 sensor, temperature range -199 to + 199°C, accuracy ± 0.5°C, resolution 0.1°C; battery backed (12 years battery life); dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD)

 

 

Caption

# 14840 / 0210 
OCTAX Log & Guard™ ultra-low temperature logger

for liquid nitrogen storage tanks; starter kit Pt1000 sensor, temperature range -199 to + 199°C, accuracy ± 0.5°C, resolution 0.1°C; battery backed (12 years battery life), cpl. with level converter supporting up to nine loggers; dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD); cpl. with small parts for installation in the tank

 

 

 

 

 

 

Caption

# 14840 / 0211
 OCTAX Log & Guard™ ultra-low temperature logger

for liquid nitrogen storage tanks; additional device Pt1000 sensor, temperature range -199 to + 199°C, accuracy ± 0.5°C, resolution 0.1°C; battery backed (12 years battery life); dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD); cpl. with small parts for installation in the tank

 

 

 

 

Caption

# 14840 / 0404

OCTAX Log & Guard™ logger for ambient temperature and humidity

Pt1000 sensor combined with a capacitive polymer humidity sensor; temperature range -25 to + 60°C, accuracy ± 0.5°C, resolution 0.1°C; humidity range 0 to 100% RH, accuracy ± 3% RH; battery backed (6 years battery life), dimensions (housing) 48.5 x 48.5 x 35.5 mm (LxWxD)

 

 

 

 

 

Caption

# 14840 / 0300 
OCTAX Log & Guard™ CO₂ sensor

Dual wavelength infrared sensor, measuring range 0 - 10% CO₂, accuracy ± 5% of the indicated value, resolution 0.1%; to be used with conventional incubators and K-Systems G185 ST; sensor diameter 43 mm, length 91 mm

 

 

 

 

 

 

 

 

 

Caption

# 14840 / 0310
 OCTAX Log & Guard™ O₂ sensor

For monitoring reduced oxygen atmosphere, measuring range 0 - 25% O₂, accuracy ± 0.5%, resolution 0.1%, sensor lifetime approx. 3 years; to be used with conventional incubators and K-Systems G185 ST; sensor diameter 43 mm, length 44 mm

 

 

 

 

 

Caption

# 28032 / 0078
K-Systems adaptor

For connecting Log & Guard™ CO₂ or O₂ sensors to the K-Systems G185ST benchtop incubator
Please note that conventional incubators must have an “access port” (small opening in the inner chamber, usually closed by a plug) for installing the Log & Guard™ sensors! All Log & Guard™ sensors must be removed from an incubator during high temperature decontamination.

The Log & Guard™ software interface offers single point calibration and adjustment dialogs for all sensor types. Calibration certificates for temperature sensors are available on request (cost option).

 

 

unique in monitoring systems: continuous VOC measurement

Caption


 

# 14840 / 0406

OCTAX Log & Guard™ VOC sensor

Detects embryotoxic volatile organic compounds (VOC) in ambient air; super-sensitive, measuring range 0 - 20 ppm (parts per million), accuracy ± 0.1 ppm, resolution 0.01 ppm; reaction time < 4 sec; detector lifetime 1 year

 

# 14840 / 0407

replacement detector for VOC sensor

Easy to replace, recommended service interval 12 months